Skip to content
  • Steve Twiss's avatar
    regulator: da9053/52: Fix incorrectly stated minimum and maximum voltage limits · 707319b6
    Steve Twiss authored
    
    
    This fix alters the minimum and maximum BUCK voltage limits for DA9052 and
    DA9053. It does so for the following cases:
    
    DA9052
    - BUCK3 (MEM)
       min: 0.925V -> 0.950V
       max: 2.500V -> 2.525V
    
    DA9053
    - BUCK3 (MEM)
       min: 0.925V -> 0.950V
       max: 2.500V -> 2.525V
    - BUCK4 (PERI)
       min: 0.925V -> 0.950V
       max: 2.500V -> 2.525V
    
    The voltage range remains the same, but the limits are shifted by +0.025V.
    
    This change is provided on DA9052:MEM, DA9053:MEM and DA9053:PERI
    and is a voltage difference of 0.025V, compared to those measured before
    this fix is applied. The patch has the effect of decreasing *all* measured
    voltages on those BUCKs when compared against the previously measured
    values for the same software voltage request.
    
    For example, with this fix applied for DA9052:MEM, DA9053:MEM and
    DA9053:PERI, the following is true.
    
    Because the previous software defined slot 0 as being 0.925V, if a request
    for 0.950V was previously sent, the slot 1 voltage would have been used.
    This would have corresponded to an actual measured voltage of 0.975V. But,
    with this patch fix, and with slot 0 properly aligned to 0.950V, if a
    voltage of 0.950V is requested by software, a measured value of 0.950V will
    be provided.
    
    Tested-by: default avatarSteve Twiss <stwiss.opensource@diasemi.com>
    Signed-off-by: default avatarSteve Twiss <stwiss.opensource@diasemi.com>
    Signed-off-by: default avatarMark Brown <broonie@kernel.org>
    707319b6