The implementation does not iterate fully over all CPU slots for every handler, leaving some of them uncollected. In addition, if maxcpus= is used to restrict the number of available CPUs to a subset of the present ones, with the highest numbered CPU marked offline, the iterator rescans the first valid IRQ slot indefinitely, eventually leading to memory corruption due to out-of-bound writes. Rewrite the iterator in order to implement the following loop as expected: for_each_irq(irq) for_each_handler_of_irq(handler, irq) for_each_online_cpu(cpu) collect_stats(irq, handler, cpu); Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
a73102d5